Used for smart meters, electrical remote control, electrical load switches, and electrical equipment.
Ordering Information
1. Part number NFE106
2. Contact arrangement
SA: A set of normally open double contacts
SB: A set of normally closed double contacts
3. Contact current: 120A
4. Coil rated voltage(V): DC:12
Contact Data
Contact Arrangement
SA SB
Contact Material
AgSnO2
Contact Rating
120A 220VAC
Max.Switching Power
26400VA
Max.Switching Voltage
220VAC Max. Switching Current 120A
Contact Resistance
≤0.5mΩ(at 120A)
Electrical Endurance
1000
Mechanical Endurance
7000
Notes: 1. SA indicates that the relay contacts are in the open state upon factory delivery; SB indicates that the relay contacts are in the closed state upon factory delivery.Unless otherwise specified by the customer, our company will default to shipping the relay with its contacts closed.
2. UC3: The product conforms to clause of GB/T 17215.231 2021: making capacity: 3kA/10ms, withstand capacity: 6kA/10ms.
Coil Parameter
Coil voltage
VDC
Coil resistance
Ω±10%
Set/Reset voltage
VDC
≤70% of rated voltage
Pulse duration
ms
Coil power
W
Set time
ms
Reset time
ms
12
12
8.4
150
12
≤30
≤30
Notes: 1.When latching relays are installed in equipment, coil should not be pulsed with less than the nominal coil voltage and pulse width should be a minimum of three times the specified operate time of the relay. If these conditions are not followed, it is possible for the relay to in be the magnetically neutral position.
2.Do not apply voltage to the coil for a long period (more than 1 minute).
Operation condition
Insulation Resistance
1000MΩ (500VDC)
Dielectric Strength
Between contacts
Between contact and coil